The MS-5UD-3 is a five-zone FACP (Fire Alarm Control Panel) and the MS-10UD-7(E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service.
Each of these FACPs is compatible with System Sensor’s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “freeze” signal when the ambient temperature falls below the detector rating. Additionally, both the MS-5UD-3 and MS- 10UD-7 are compatible with conventional input devices such
as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices.
Outputs include four NACs (Notification Appliance Circuits), three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application
resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity.
Activation of a compatible smoke detector or any normally open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function.
New options include a UL listed printer, PRN-6F and FireLite’s new IPDACT Internet Monitoring module. The IPDACT permits monitoring of alarm signals over the Internet saving the
monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.
Features:
• Listed to UL Standard 864, 9th edition.
• Built-in DACT (Digital Alarm Communicator/Transmitter).
• Style B (Class B) IDC (Initiating Device Circuit)
– MS-5UD-3 - five IDCs.
– MS-10UD-7 - ten IDCs.
• Style Y (Class B) NAC (Notification Appliance Circuit) - special
application power
– MS-5UD-3 - four NACs.
– MS-10UD-7 - four NACs.
• Notification Appliances may be programmed as
– Silence Inhibit.
– Auto-Silence.
– Strobe Synchronization for System Sensor, Wheelock,
Gentex, Faraday, or Amseco devices.
– Selective Silence (horn-strobe mute).
– Temporal or Steady Signal.
– Silenceable or Nonsilenceable.
• Optional CAC-5X Style Z (Class A) Converter Module for
NACs and IDCs (2 required for MS-10UD-7).
• Form-C Relays for Alarm, Trouble and Supervisory - Contact
Ratings 2.0 A@ 30 VDC or 30 VAC (resistive).
• 3.0 A total system current for MS-5UD-3.
• 7.0 A total system current for MS-10UD-7.
• Optional Dress Panel DP-51050
• Optional Trim Ring TR-CE for semi-flush mounting.
• 24 volt operation.
• Low AC voltage sense.
• Alarm Verification.
• PAS (Positive Alarm Sequence).
• Automatic battery trickle charger.
• Up to eight ANN-BUS annunciators:
– Optional 8 zone Relay Module ANN-RLY.
– Optional LED Annunciator Module ANN-LED,
– Optional Remote Annunciator ANN-80.
– Optional Remote Printer Gateway ANN-S/PG.
– Optional LED Annunciator Driver ANN-I/O.
• Optional 4XTMF module (conventional reverse polarity/city
box transmitter).
Controls and Indicators:
LED INDICATORS:
• FIRE ALARM (red)
• SUPERVISORY (yellow)
• TROUBLE (yellow)
• AC POWER (green)
• ALARM SILENCED (yellow)
CONTROL BUTTONS
• ACKNOWLEDGE
• ALARM SILENCE
• SYSTEM RESET (lamp test)
• DRILL